In the vacuum salt making system, the raw material is brine, which contains a large amount of corrosive medium. Its main equipment, such as brine preheaters, heaters, and evaporation tanks, are exposed to high-concentration brine for a long time at relatively high temperatures, and are constantly impacted by salt and sand. Under such conditions, the equipment must operate normally for a long time, and anti-corrosion is the key. question.
There are many reasons for corrosion, among which the presence of O2, high temperature, Cl- and solid salt washout are the main factors. Commonly used anti-corrosion methods include deoxidation, pH adjustment, electrochemical protection, coating protection, and the use of anti-corrosion materials. Among them, the use of anti-corrosion materials is a very effective way of anti-corrosion, and the application of titanium and titanium alloys in vacuum salt production is one example.
Preheater
The raw material needs to be preheated before entering the heater to save energy. The preheater used to be a tube-and-tube heat exchanger. The heat exchange tube material was made of carbon steel, which was easy to block and corrode through the tube. The heat exchange tube was often replaced and the production was stopped for maintenance, which brought great inconvenience to production. There are also preheaters that use red copper tubes, the corrosion still exists, the service life is extended to 1 year, but it is still very short, and the cost of copper tubes is high.
Until the advent of titanium plate heat exchangers. The heat exchange surface of the plate heat exchanger is a plate, although the strength is not as good as that of the tubular heat exchanger, but its heat transfer effect is good, the material is small, the weight is light, and it is easy to maintain, and its service life can reach 15 years. For example, and the Gr9 Ti-3Al-2.5V Titanium Sheet is still as bright as new, and has never been replaced, and the economic benefits are obvious.
heater
Since the heat exchange tubes of the heater are densely arranged on the tube sheet, maintenance and repairs are quite time-consuming, and all the heating tubes need to be replaced once a year. The temperature of effect II and effect III is lower, and the heating tube can be used for about 2 years. The temperature of the IV effect is the lowest and it can only be used for 4 years and needs to be replaced. During the overhaul, the shutdown delays the production, the output is reduced, the production is seriously affected, and the maintenance cost is high (some manufacturers use red copper for the heating room, the situation has improved, but the I effect is used. The period is no more than 3-5 years). In view of the characteristics of titanium, if titanium is used in heaters, the situation will be greatly improved.